High Fire proof LSZH Fire Alarm Cable 1AWG for Government School Hospital Fire Alarm System Descripition: Conductor: 18AWG Soild Cooper Insulation: LSZH Shield: 0.001 inch Aluminum/Mylar Drain: 24 AWG Solid Tined Copper Jacket: LSZH Nominal Insulation Thickness: 0.008 inches Nominal Jacket...

Send Inquiry

High Fire proof LSZH Fire Alarm Cable 1AWG for Government School Hospital Fire Alarm System


Descripition:

Conductor:18AWG Soild Cooper

Insulation: LSZH

Shield:0.001 inch Aluminum/Mylar

Drain:24 AWG Solid Tined Copper

Jacket:LSZH
Nominal Insulation Thickness: 0.008 inches
 Nominal Jacket Thickness: 0.014 inches
Outside Diameter: 0.151 inches



Features:
Two bare copper insulated conductors with an overall shield and a drain. The assembly has an overall jacket. Rated for use from -20°C to +60°C. Suggested voltage rating: 300 volts.


Basic Fire Alarm Systems

Most fire alarm systems fall into two categories: conventional or addressable. Conventional fire alarm systems are a simple, common,     time-proven technology, which protect a large percentage of commercial     buildings today. Their reliability and low cost make them ideal for small     to medium size properties. Conventional fire alarm systems are     characterized by a fire alarm control panel, which holds the entire     system's intelligence. Connected to this panel via hard wires are a     number of detectors or initiating devices such as smoke, flame or heat     detectors. Additionally, the control panel is wired to notification devices     such alarm bells, strobe lights and automatic dialers.

Fire alarm systems serve as a life line and a connection to first responders. When a signal is transmitted to central monitoring center, failure is not an option, it must be guaranteed. Conventional Fire Alarm Systems have been around for many years and have changed little. They provide well proven technology protecting many hundreds of thousands of properties worldwide.


Application:

Fire alarm cables may be used in smoke alarms and detectors, voice communications, addressable fire alarm systems, microprocessor controlled systems, pull boxes, burglar alarms, wiring of fire alarms, and fire protective circuits.


Our advantage:

We have special recipe in the Jacket so that can make it strong function in fire proof. It won't smoking or release toxic gas in a long time make sure people have enough time to get away from the fire. That's most important.


Construction & Material

Item
Specification
Product
High Grad LSZH Fire Alarm Cable
Conductor
Construction
Soild 2×18AWG
Material
Bare Copper
Insulation
Material
LSZH
Min. Thickness

Avg. Thickness
0.245mm
Diameter
1.524mm
Nom. Lay Length
114mm
Color
Variety Color Choices
Jacket
Material

LSZH

Min. Thickness


Avg. Thickness
0.508mm
Diameter
4.318mm
Color
Variety Color Choices
Approximate Cable Weight
20 Ibs/Kft



Z6%MW)_L)JJWA$174K4MO05.png

Electrical Properties
Nom. DC Resistance Per Conductor @20℃6.43 Ohms/Kft.nom.
Capacitance Between Conductor@1KHz
35 pF/ ft.nom.
Operating Voltage
300V / RMS max.
Temperature Rating
-20℃ to 60℃