2 Core Fire Alarm Cable For Fire Alarm Security System

2 Core Fire Alarm Cable for Fire Alarm Security System Descrip Tion 1 Solid or stranded,tinned or bare or copper conductor 2 Fire resistant PVC insulation and jacket 3 Fiberglass tape.AL foil,Pet foil,or no Fire resistant cable has been specially designed and thoroughly tested to retain its...

Send InquiryChat Now

2 Core Fire Alarm Cable for Fire Alarm Security System


Descrip Tion

1 Solid or stranded,tinned or bare or copper conductor
2 Fire resistant PVC insulation and jacket
3 Fiberglass tape.AL foil,Pet foil,or no

 

Item No. Description Conductor
Spec.
Insulation Jacket Approximate
Cable
weight
Conductor
resistance
Current
ratings
Voltage
drop
Packing
Nom.Thick.(m m) Nom.Diam.(m m) Nom.Thick.(m m) Nom.Diam.(m m)
AW-FPC208 BC/TC

solid or stranded

Shielded or
unshielded

PVC
Insulation
Jacke
2*0.8mm2 0.5 2.0 0.7 5.4 40KG/KM 24Ω/KM 18A 61.2 V/M
Box
Coil
Drum
Paper reel
Plastic reel
Wooden reel
AW-FPC308 3*0.8mm2 0.5 2.0 0.7 5.7 51KG/KM 24Ω/KM 18A 61.2 V/M
AW-FPC408 4*0.8mm2 0.5 2.0 0.75 6.6 66KG/KM 24Ω/KM 18A 61.2 V/M
AW-FPC210 2*1.0mm2 0.55 2.25 0.75 6.2 48KG/KM 18.1Ω/KM 20A 46.2 V/M
AW-FPC310 3*1.0mm2 0.55 2.25 0.75 6.5 63KG/KM 18.1Ω/KM 20A 46.2 V/M
AW-FPC410 4*1.0mm2 0.55 2.25 0.8 7.3 80KG/KM 18.1Ω/KM 20A 46.2 V/M
AW-FPC215 2*1.5mm2 0.6 2.6 0.8 7.0 64KG/KM 12.1Ω/KM 25A 30.9 V/M
AW-FPC315 3*1.5mm2 0.6 2.6   7.4 85KG/KM 12.1Ω/KM 25A 30.9 V/M
AW-FPC415 4*1.5mm2 0.6 2.6 0.85 8.3 105KG/KM 12.1Ω/KM 25A 30.9 V/M
AW-FPC225 2*2.5mm2 0.6 3.0 0.8 7.8 87KG/KM 7.41Ω/KM 34A 18.9 V/M
AW-FPC325 3*2.5mm2 0.6 3.0 0.8 8.2 118KG/KM 7.41Ω/KM 34A 18.9 V/M
AW-FPC425 4*2.5mm2 0.6 3.0 0.85 9.2 151KG/KM 7.41Ω/KM 34A 18.9 V/M
 

Fire resistant cable has been specially designed and thoroughly tested to retain its durability and reliability when fire strikes.

A fire alarm system is reliant in no small part to the cabling that connects the devices and supplies power. Without reliable, robust cable the fire alarm system would be prone to costly faults and malfunctions. It is therefore essential that you only use the best cable, fitted by qualified electricians, in your fire alarm system.

In a fire emergency the fire alarm system in your building has to continue working for a significant period of time therefore circuit integrity is essential. The effects of fire could cause standard cable to melt or transmit fire to other parts of the building so it's essential to ensure that your fire alarm system cable is also fire resistant.

Fire resistant cable, or fireproof cable, will resist the effects of fire to go on working and providing communication and power throughout the fire alarm system while being exposed to fire for an impressive length of time.

Special materials used in the manufacture of fire resistant cable provides the fire resistant qualities. The cable, once complete, must meet stringent testing and regulations in order to be approved for use in fire alarm systems.

2 Core Fire Resistant Cable, for example, has a very high operating temperature. This is in part due to a low-polymer outer sheathing bonded with aluminium foil as well as fire resistant silicon core insulation. The copper cables themselves are tin annealed to improve strength and heat resistance.